EXXON CHEMICAL AMERICAS/A DIV OF EXXON CORP -- CHARCOAL LIGHTER 105 -- 9160-00N091547
=====================  Product Identification  =====================

Product ID:CHARCOAL LIGHTER 105
MSDS Date:05/23/1996
FSC:9160
NIIN:00N091547
Status Code:A
MSDS Number: CJLZT
=== Responsible Party ===
Company Name:EXXON CHEMICAL AMERICAS/A DIV OF EXXON CORP
Address:13501 KATY FWY
Box:3272
City:HOUSTON
State:TX
ZIP:77253-3272
Country:US
Info Phone Num:713-870-6000
Emergency Phone Num:800-726-2015
Resp. Party Other MSDS Num.:92886533
Chemtrec Ind/Phone:(800)424-9300
CAGE:72190
=== Contractor Identification ===
Company Name:ARROW WEST
Country:US
Phone:214-418-9708
CAGE:TO279
Company Name:EXXONMOBIL CHEMICAL CO, DIV OF EXXON MOBILCORP.
Address:13501 KATY FWY
Box:3272
City:HOUSTON
State:TX
ZIP:77253-3272
Country:US
Phone:281-870-6000 / 800-726-2015
CAGE:72190

=============  Composition/Information on Ingredients  =============

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (ALIPHATIC HYDROCARBON)
CAS:64742-47-8
RTECS #:OA5504000

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT: SLIGHTLY IRRITATING BUT
    DOES NOT INJURE EYE TISSUE. SKIN: LOW ORDER OF TOXICITY. FREQUENT
    OR PRLNGD CONTACT MAY IRRITATE AND CAUSE DERMATITIS. INHAL: HIGH
    VAPOR/AEROSOL CONCENTRATIONS (GR EATER THAN APPROXIMATELY 1000 PPM)
    ARE IRRITATING TO EYES AND RESPIRATORY TRACT, MAY CAUSE HEADACHES,
    DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS AND OTHER
    CENTRAL NERVOUS SYSTEM EFFECTS, INCLU DING DEATH. INGEST: SMALL
    AMOUNTS OF THIS PRODUCT ASPIRATED INTO RESPIRATORY SYSTEM DURING
    INGESTION OR VOMITING MAY CAUSE MILD TO SEVERE PULMONARY INJURY,
    POSSIBLY PROGRESSING TO DEATH. MINIMAL TOXIC ITY.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
    EXISTING DERMATITIS CONDITION.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH EYES W/LARGE AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES UNTIL IRRITATION SUBSIDES. IF IRRITATION PERSISTS, GET
    MEDICAL ATTENTION. SKIN: FLUSH W/LARGE AMOUNTS OF WATER; USE SOAP
    IF AVAILABLE.  REMOVE GROSSLY CONTAMINATED CLOTHING, INCLUDING
    SHOES & LAUNDER BEFORE REUSE. INHALATION: USING PROPER RESPIRATORY
    PROTECTION, IMMEDIATELY REMOVE THE AFFECTED VICTIM FROM EXPOSURE.
    ADMINISTER ARTIFIC IAL RESPIRATION IF BREATHING IS STOPPED. KEEP AT
    REST. CALL FOR PROMPT MEDICAL ATTENTION. INGESTION: IF SWALLOWED,
    DO NOT INDUCE VOMITING. KEEP AT REST. GET PROMPT MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:=37.8C, 100.F
Autoignition Temp:=232.2C, 450.F
Autoignition Temp Text:APPROX
Lower Limits:1.4%
Upper Limits:8.9%
Extinguishing Media:USE FOAM, DRY CHEMICAL OR WATER SPRAY TO EXTINGUISH
    FIRE. USE WATER SPRAY TO COOL FIRE EXPOSED SURFACES & TO PROTECT
    PERSONNEL.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
    ISOLATE "FUEL" SUPPLY FROM FIRE. AVOID SPRAYING WATER DIRECTLY INTO
    STOR CNTNRS DUE TO DANGER OF BOILOVER. LIQ IS VOLAT & GIVES OFF
    INVISIBLE VAPS. EITH ER LIQ/VAP MAY SETTLE IN LOW AREAS/TRAVEL SOME
    DIST ALONG GROUND/SURF TO IGNIT SOURCES WHERE THEY MAY
    IGNITE/EXPLODE.
Unusual Fire/Explosion Hazard:COMBUST LIQ CAN FORM COMBUST MIXS AT
    TEMPS AT/ABOVE FL PT. STATIC DISCHARGE MATL CAN ACCUM STATIC
    CHARGES WHICH CAN CAUSE INCENDIARY ELEC DISCHARGE. "EMPTY" CNTNRS
    RETAIN PROD RESIDUE (LIQ &/OR VAP) &  CAN BE DANGEROUS. DO NOT
    PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND OR EXPOSE SUCH
    CNTNRS (TOXICOLOGICAL INFO)

==================  Accidental Release Measures  ==================

Spill Release Procedures:LAND SPILL: ELIM SOURCES OF IGNIT. PVNT ADDNL
    DISCHARGE OF MATL IF POSS TO DO SO W/OUT HAZ. FOR SM SPILLS
    IMPLEMENT CLEANUP PROCS; FOR LG SPILLS IMPLEMENT CLEANUP PROCS &,
    IF IN PUBLIC AREA, KEEP PUBL IC AWAY & ADVISE AUTHS. ALSO, IF PROD
    IS SUBJECT TO CERCLA REPORTING (SEE REGULATORY INFO) NOTIFY NRC.
    PVNT LIQ FROM ENTERING SEWERS, WATERCOURSES OR LOW AREAS. CNTN
    SPILLED LIQ W/SAND OR (SUPDAT)

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORAGE TEMP & LOADING/UNLOADING
    TEMP:AMBIENT. STORAGE/TRANSPORT PRESS: ATMOSPHERIC.
    LOADING/UNLOADING VISCOSITY, EST:1.3. KEEP CNTNR CLSD. HNDL & OPEN
    CNTNRS W/CARE. STORE IN COOL, WELL VENTD PLACE A WAY FROM INCOMPAT
    MATLS. DO NOT HANDLE OR STORE NEAR OPEN FLAME, HEAT OR OTHER 
    (STATE REG INFO)
Other Precautions:ELECTROSTATIC ACCUM HAZ: YES, USE PROPER GROUNDING
    PROC. ADDNL INFO REGARDING SAFE HNDLG OF PRODS W/STATIC ACCUM
    POTNTL CAN BE ORDERED BY CONTACTING AMERICAN PETRO INSTITUTE (API)
    FOR API RECOM PRACT  2003, ENTITLED "PROT AGAINST IGNITS ARISING
    OUT OF STATIC, LIGHTING & STRAY CURRENTS" (TOXICOLOGICAL  INFO)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:WHERE CONCENTRATIONS IN AIR MAY EXCEED THE
    LIMITS (EXXON RECOMMENDS THE FOLLOWING OCCUPATIONAL EXPOSURE
    LIMITS: 300 PPM TOTAL HYDROCARBON BASED ON COMPOSITION) &
    ENGINEERING, WORK PRACTICE OR OTHER ME ANS OF EXPOSURE REDUCTION
    ARE NOT ADEQUATE, NIOSH APPROVED RESPIRATORS MAY BE NECESSARY TO
    PREVENT OVEREXPOSURE BY INHALATION.
Ventilation:USE OF MECHANICAL DILUTION VENTILATION IS RECOMMENDED
    WHENEVER THIS PRODUCT IS USED IN A CONFINED SPACE, IS HEATED ABOVE
    AMBIENT TEMPS OR IS AGITATED.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH AND DELUGE SHOWER MEETING ANSI
    DESIGN CRITERIA . WEAR LONG SLEEVES.
Supplemental Safety and Health
SPILL PROC: EARTH. DO NOT USE COMBUST MATLS SUCH AS SAWDUST. RECOVER BY
    PUMPING (USE EXPLO PROOF OR HAND PUMP) OR W/SUITABLE ABSORB.
    CONSULT EXPERT ON DISP OF RECOVERED MATL & ENSURE CONFORMITY TO LOC
     DISP REGS. WATER SPILL: ELIM SOURCES OF IGNIT. WARN OCCUPANTS &
    SHIPPING IN SURROUNDING & DOWNWIND (OTHER INFO)

==================  Physical/Chemical Properties  ==================

Boiling Pt:>157.2C, 315.F
B.P. Text:315-390 APPROXIMATE
Melt/Freeze Pt:<-60.C, -76.F
Vapor Pres:2 MMHG @ 68F APPROX
Spec Gravity:0.78 @ 60F
Viscosity:1.3 @ 77F APPROXIMATE
Evaporation Rate & Reference:0.1 APPROX N-BU ACETATE=1
Solubility in Water:<0.01 & 77F
Appearance and Odor:CLEAR COLORLESS LIQUID.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:NONE.

===================  Toxicological Information	===================

Toxicological Information:PLEASE REFER TO SECTION ON HEALTH HAZARDS FOR
    AVAILABLE INFO ON POTENTIAL HEALTH EFFECTS. OTHER PRECS: (AMERICAN
    PETRO INSTITUTE, 1720 L ST NW, WASHINGTON, DC 20005), OR NATIONAL
    FIRE PROTECTION ASSOC  (NFPA) FOR NAPA 77 ENTITLED "STATIC ELEC"
    (NFPA, 1 BATTERYMARCH PARK, BOX 9101, QUINCY MA 02260-0101). EXPLO
    HAZ: TO HEAT, FLAME, SPARKS, STATIC ELEC OR OTHER SOURCES O IGNIT;
    THEY MAY EXPLODE & CAUS E INJURY OR DEATH. EMPTY DRUMS SHOULD BE
    COMPLETELY DRAINED, PROPERLY BUNGED & PROMPTLY RETURNED TO DRUM
    RECONDITIONER OR PROPERLY DISPOSED OF. DECOMP PRODS UNDER FIRE
    CNDTNS:NO UNUSUAL.

=====================  Ecological Information  =====================

Ecological:NO SPECIFIC ECOLOGICAL DATA ARE AVAILABLE FOR THIS PRODUCT.
    PLEASE REFER TO SPILL PROCEDURES FOR INFORMATION REGARDING
    ACCIDENTAL RELEASES AND REGULATORY INFO FOR REGULATORY REPORTING
    INFO. FED REG IN FO: WE RECOMMEND YOU CNTCT LOCAL AUTHORITIES TO
    DETERMINE IF THERE MAY BE OTHER LOCAL REPORTING REQS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
    STATE AND LOCAL REGULATIONS . PLEASE REFER TO SECTIONS ON FIRE
    FIGHTING MEASURES, ACCIDENTAL RELEASE MEASURES, AND REGULATORY
    INFORMATION FOR DISPOSA L AND REGULATORY INFORMATION.

===================  MSDS Transport Information  ===================

Transport Information:DOT SHIPPING DESCRIPTION: PETROLEUM DISTILLATE,
    N.O.S., COMBUSTIBLE LIQUID. UN 1268. III. NOTE: IN CONTAINERS OF
    119 GALLONS CAPACITY OR LESS THIS PRODUCT IS NOT REGULATED BY DOT.

=====================  Regulatory Information  =====================

SARA Title III Information:UNDER PROVISIONS OF TITLE III, SECTIONS
    311/312 OF THE SUPERFUND AMENDMENTS & REAUTHORIZATION ACT, THIS
    PROD IS CLASSIFIED INTO FOLLOWING HAZ CATEGORY: FIRE. THIS INFO MAY
    BE SUBJECT TO PROVISIONS OF  COMMUNITY RIGHT-TO-KNOW REPORTING REQS
    (40 CFR 370) IF THRESHOLD QTY CRITERIA ARE MET. THIS PROD DOES NOT
    CNTN SECTION 313 REPORTABLE INGREDS.
Federal Regulatory Information:PROD IS HAZ AS DEFINED IN 29 CFR
    1910.1200. OSHA HAZ: COMBUST. PROD IS LISTED ON TSCA INVENTORY AT
    CAS #64742-47-8. PROD IS CLASSIFIED AS OIL UNDER SECTION 311 OF
    CLEAN WATER ACT (40 CFR 110) & OIL PO LLUTION ACT OF 1990.
    DISCHARGE/SPILLS WHICH PRDCE VISIBLE SHEEN AT EITHER SURF WATER OR
    IN WATERWAYS/SEWERS WHICH LEAD TO SURF WATER OR IN WATERWAYS/SEWERS
    WHICH CAN LEAD TO SURF WATER, MUST BE REPORT ED TO NRC AT
    800-424-8802. IF PROD IS ACCIDENTALLY SPILLED, IT IS NOT SUBECT TO
    ANY SPECIAL REPORTIN G UNDER REQS OF COMPREHENSIVE ENVIRONMENTAL
    RESPONSE COMPENSATION & LIABILITY ACT (CERCLA). (ECOLOGICAL INFO)
State Regulatory Information:OTHER INFO: SINKING &/OR SUITABLE
    DISPERSANTS MAY BE USED IN NON-CONFINED WATERS. CONSULT EXPERT ON
    DISP OF RECOVERED MATL & ENSURE CONFORMITY TO LOC DISP REGS.
    HNDLG/STOR: SOURCES OF IGNIT. PROTECT M ATL FROM DIRECT SUNLIGHT.
    MATL WILL ACCUMULATE STATIC CHARGES WHICH MAY CAUSE ELEC SPARK
    (IGNIT SOURCE). USE PROPER GROUNDING PROCS. DO NOT PRESSURIZE, CUT,
    HEAT OR WELD CNTNRS. EMPTY PROD CNTNRS MAY	CONTAIN PROD RESIDUE.
    DO NOT REUSE EMPTY CNTNRS W/OUT COMMERCIAL CLEANING OR
    RECONDITIONING.

=======================  Other Information  =======================

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.